We’re Just a Call Away!
Need help? Give us a call for a free consultation with one of our specialists.
Mobility Scooters, Sunshine Coast
Book your Home Trial with Kineticare
Currently servicing Sunshine Coast and Brisbane areas. Book a personalised home trial, where you can test our premium products in the comfort of your own home, guided by our expert team and in collaboration with occupational therapists. Contact Kineticare today to book your no-obligation home trial and take the first step towards finding your ideal mobility solution.Please note that this is not available for all products, including beds, mattresses and bathroom products. Trials are subject to the product availability too.
At Kineticare, we're committed to offering not only the highest quality mobility solutions but also the best value for our clients. That's why we proudly introduce our Price Beat Guarantee. If you find a lower price from an identical local competitor, we promise to not just match it, but beat it. We're committed to providing you with premium products at unbeatable prices, ensuring you can choose Kineticare with confidence for all your mobility needs.
Experience the Kineticare difference - superior products, unparalleled service, and our Price Beat Guarantee. Contact us today to learn more!
FULL VAPOUR PERMEABILITY
According to the Prevention and Treatment of Pressure Injuries: Clinical Practice Guideline, The International Guideline 2019 – Trans-epidermal water lows (TEWL) and sweating may result in the accumulation of moisture between the individual and the support surface if the surface does not allow for transmission or evaporation of the moisture away from the interface.
The combination of a foam mattress cover and the foam itself creates resistance to moisture transmission. Moisture accumulation will increase the friction between the individual and the surface. A mattress with a high vapour transmission rate (MVTR) potentially allows the moisture to transpire through the cover. A lower mattress cover MVTR protects the foam from moisture degradation.
Selecting a cover based on MVTR becomes a compromise between managing skin microclimate and the individual’s TEWL. It is recommended that a high specification mattress should have a cover with an MVTR ≥ 300g/m2/24hrs (equivalent to normal TEWL).
On the Premiflex Ultra cover, The PFPU1100 Upper material is tested to 500g/m2/24hrs, and the PFPU1200 Base material is tested to 300g/m2/24hrs.
The Premiflex Ultra cover has been designed to have full vapour permeability i.e. all materials used are a vapour permeable/breathable polyurethane material. Vapour permeable polyurethane wicks away moisture from the patient’s skin and allows it to escape through the base of the mattress – reducing the heat at the patient interface, providing for improved skin micro-climate conditions.
Many polyurethane pressure care covers are designed with a polyurethane, vapour permeable upper material and a PVC or fully waterproof base. Without a vapour permeable base, moisture cannot escape the base of the mattress and as such, over time moisture will build up and turn into mould.
The Base material on the Premiflex Ultra is a double coated vapour permeable polyurethane which is extra durable to protect the foam core against the bed bae (especially one that profiles). In addition, a polyurethane base material will provide more grip to the bed platform.
Does this mean your mattress cover is not waterproof? No, it is wipe-clean and considered waterproof by most. Liquid droplets are too large to penetrate through the cover. The liquid will only transpire through the cover in the form of vapour, so wipe clean any spills before the liquid turns to vapour.
RESISTANCE TO CLEANING AGENTS
Cleaning and infection control is now a bigger concern than ever before. However, it is important that soft surfaces, such as mattresses, are cleaned using the correct cleaning agents otherwise there is risk of damaging the equipment or spoiling it to the extent that it becomes an infection risk. For example, Usage of high concentrations of Phenol-based and Chlorine chemicals or abrasive cleaning agents can have a negative impact on the integrity of the mattress fabric coatings over time.
Forté Premiflex fabrics have been designed to have a high resistance to cleaning agents which means a broader range of strong cleaning chemicals can be used to clean the surface without compromising on the performance and longevity of the mattress.
Premiflex fabrics have been designed and tested to withstand cleaning agents with 15,000ppm of active chlorine. Forté stipulates a maximum chlorine concentration of 10,000ppm for all Premiflex fabrics. As such, facilities can have confidence that their covers will perform under strong and consistent cleaning regimes – and more chance of cover-material longevity when the wrong cleaning agent or method is used – a common scenario in any care environment.
Premiflex covers provide the highest available level of infection control for a polyurethane pressure care cover.
UNIQUE FORTÉ FORMULATION
Forté has developed an exclusive range of fabrics that are manufactured in Belgium and converted by Forté into Pressure Care covers in our Armidale NSW manufacturing facility. Close collaboration with clinicians, years of experience in developing support surfaces for the medical application and partnerships with leading medical fabric producers, has allowed Forté to create these unique fabrics. Forté specified properties such as vapour permeability, stretch, and longevity create some of the highest performing covers available.
What is the benefit of using covers with fabrics specified by Forté? Guarantee that materials used are leading cover technology designed specifically to suit Australian standards and care environments.
INFECTION CONTROL
Effective infection prevention and control are central to providing high quality healthcare for patients and a safe working environment for those who work in healthcare settings. The Australian Guidelines for the Prevention and Control of Infection in Healthcare (AGPIH) provide evidence-based recommendations that outline the critical aspects of infection prevention and control, focusing on core principles and priority areas for action.
The AGPIH describe the best way to prevent and reduce infections occurring in healthcare settings including resistant infections. The AGPIH include how to manage common infectious agents, for example, gastrointestinal viruses and evolving infectious agents, for example, influenza or multi-drug resistant organisms.
Any infectious agents introduced into the body can establish infection. In all healthcare settings, reusable medical devices, such as mattresses, should be handled in a manner that will prevent patients, healthcare workers and environmental contact with potentially infectious material. Post COVID-19 pandemic, Cleaning and infection control have become a bigger concern than ever before.
Appropriate reprocessing or precautions must be implemented for mattresses and other reusable equipment, to prevent patient-to-patient transmission of infectious agents.
Principles of reprocessing reusable medical devices include:
Only Therapeutic Goods Administration (TGA)-included reusable medical devices should be used; before purchase, healthcare facilities should ensure that manufacturer’s reprocessing instructions are provided and are able to be followed by the healthcare facility.
All reusable medical devices and patient-care equipment used in the clinical environment must be reprocessed according to their intended use and the manufacturer’s advice.
However, Other standard precautions must take place. Standard precautions are basic infection prevention and control strategies that apply to everyone, regardless of their perceived or confirmed infectious status. Strategies include hand hygiene, personal protective equipment, cleaning, and appropriate handling and disposal of sharps. These are the first-line approach to infection prevention and control in health service organisations and are routinely applied as an essential strategy for minimising the spread of infections. Standard precautions minimise the risk of transmission of infectious agents from one person or place to another, even in high-risk situations, and render and maintain objects and areas as free as possible from infectious agents
Specifically, in relation to the support surface, there should be no exposed materials that will absorb fluid. As such, every mattress cover in the facility environment must have high-frequency welded seams (as opposed to sewn) to meet infection control requirements and prevent seepage of fluid through open sewn seams which leave thousands of tiny holes in the seam. These electromagnetically fused seams protect against the risk of penetration fluid as they 100% seal off to prevent ingress of fluid or infection. To ensure extra strength, Forté reinforces welded seams with additional Intra-weld heavy duty stitching at stress points within the cover.
In addition, Forté mattress covers, and foam cores are inherently treated with anti-microbial agents to prevent the growth of mould and bacteria on soft surfaces. It is a recommendation that soft surfaces must be impregnated with antimicrobial (self-disinfecting) materials.
All Forté products are included and registered on the Australian Register of Therapeutic Goods (ARTG). Unless exempt, reusable medical devices must be ‘included’ in the ARTG before they may be supplied in Australia.
Forté mattresses can withstand stringent infection control procedures and have been designed to suit facility standards so you can have peace of mind that all areas of your facility are safe, clean environments for staff and patients.
Sizes and Availability
COVPUS1000-1 - Made to Order - Single
COVPUSL1000-1 - Made to Order - Long Single
COVPUKS1000-2 - Made to Order - King Single
COVPUKSL1000 - Made to Order - Long King Single
COVPUEW1000-1 - Made to Order - Extra Wide
COVPUEWL1000-1 - Made to Order - Long Extra Wide
COVPUD1000-1 - Made to Order - Double
COVPUDL1000-1 - Made to Order - Long Double
COVPUQ1000-1 - Made to Order - Queen
COVPUQL1000-1 - Made to Order - Long Queen
COVPUK1000 - Made to Order - King
COVPUKL1000-1 - Made to Order - Long King
COVPUSQ1000-1 - Made to Order - Split Queen
COVPUSQL1000-1 - Made to Order - Long Split Queen
As a registered NDIS provider, Kineticare recognises the significance of collaborating with plan managers and NDIS participants to deliver optimal support and care.
Kineticare is committed to providing high-quality, cost-effective, and accessible back care and mobility products to NDIS participants throughout Australia. We take pride in being a reliable partner for plan managers and the broader disability community. For more information or to request a quote, please click the link above or click here.
Book your Home Trial with Kineticare
Currently servicing Sunshine Coast and Brisbane areas. Book a personalised home trial, where you can test our premium products in the comfort of your own home, guided by our expert team and in collaboration with occupational therapists.
Contact Kineticare today to book your no-obligation home trial and take the first step towards finding your ideal mobility solution.
Please note that this is not available for all products, including beds, mattresses and bathroom products. Trials are subject to the product availability too.
Book your Home Trial with Kineticare
Currently servicing Sunshine Coast and Brisbane areas. Book a personalised home trial, where you can test our premium products in the comfort of your own home, guided by our expert team and in collaboration with occupational therapists. Contact Kineticare today to book your no-obligation home trial and take the first step towards finding your ideal mobility solution.Please note that this is not available for all products, including beds, mattresses and bathroom products. Trials are subject to the product availability too.
Thanks for subscribing!
This email has been registered!
Product | SKU | Rating | Description | Collection | Availability | Product Type | Other Details |
---|
Need help? Give us a call for a free consultation with one of our specialists.